Ongoing projects
link
Latest news on validation - November 2003
A reconfiguration of the MIPAS processor has been implemented on 4 November 2003.
See the email of Rob Koopman.
ORM team
IFAC-CNR Firenze-Italy Bruno Carli Piera Raspollini Simone Ceccherini Maria Prosperi Claudio Belotti |
ISAC-CNR Bologna-Italy Bianca Maria Dinelli Elisa Castelli Didem Alpaslan Luca Magnani |
University of Bologna Bologna-Italy Massimo Carlotti Marco Ridolfi |
IMK - FZK Karlsruhe - Germany Hermann Oelhaf Michael Höpfner |
University of Leicester Leicester - England John Remedios Reinhold Spang |
LPM-CNRS Paris - France Jean-Marie Flaud |
Oxford University Oxford - England Anu Dudhia Chiara Piccolo Vivienne Payne |
MEASUREMENTS on August-September 2004
These measurements were performed using the original vertical sampling grid but with reduced spectral resolution.
Type |
Parameters |
Spectral resolution |
0.0625 cm-1 (defined as spacing between independent measured spectral points) |
Vertical sampling grid # of spectra / scan |
3 km step 5 km step 8 km step 6-42 km 42-52 km 52-68 km 17 |
Horizontal sampling grid |
220 km |
MEASUREMENTS from January 2005 on
These measurements have been performing using the reduced spectral resolution and a vertical sampling grid that is finer than the one used at the beginning of the MIPAS mission.
Type |
Parameters |
Spectral resolution |
0.0625 cm-1 (defined as spacing between independent measured spectral points) |
Vertical sampling grid # of spectra / scan |
1.5 km step 2 km step 3 km step 4km step 6-21 km 21-31 km 31-46 km 46-70 km 27 |
Horizontal sampling grid |
400 km |
MEASUREMENTS from June 2002 to March 2004
These measurements were performed in the nominal measurement scenario that had originally been planned.
The characteristics distinguishing the June 2002 - March 2004 measurements from the subsequent measurements are listed below:
The characteristics distinguishing the June 2002 - March 2004 measurements from the subsequent measurements are listed below:
Type |
Parameters |
Spectral resolution |
0.025 cm-1 (defined as spacing between independent measured spectral points) |
Vertical sampling grid # of spectra / scan |
3 km step 5 km step 8 km step 6-42 km 42-52 km 52-68 km 17 |
Horizontal sampling grid |
550 km |